Seawater Desalination: Water, water, Everywhere
0 comments Posted by Energy Recovery Inc. at 6:06 PMWater-short California's search to satisfy its thirst is beginning to focus on a controversial source -- the Pacific Ocean.
In November, Connecticut-based Poseidon Resources Corp. won a key regulatory approval to build a $300 million water-desalination plant in Carlsbad, north of San Diego. The facility would be the largest in the Western Hemisphere, producing 50 million gallons of drinking water a day, enough to supply about 100,000 homes.
Taking the salt out of seawater is a common way to produce drinking water in the Middle East and in other arid regions. World-wide, 13,080 desalination plants produce more than 12 billion gallons of water a day, according to the International Desalination Association.
But it has been less successful in the U.S. Desalination is more expensive than traditional sources, and critics say it harms the ocean. In 1992, Santa Barbara, Calif., shuttered a small plant after three months when rain replenished the county's main water sources. At a plant near Tampa, Fla., that Poseidon was also involved in, technical glitches increased the water's cost and, when it opened in 2003, initially limited output to less than a third of the projected 25 million gallons a day.
Southern California water officials say conditions have changed. Improved technology has cut the cost of desalination in half in the past decade, making it more competitive. And traditional water supplies, such as the Colorado River and snow-melt runoff, are becoming less reliable because of population growth and environmental restrictions.
"We have to get our water from somewhere, and it's going to be the Pacific Ocean," says Gary Arant, manager of the Valley Center Municipal Water District, which serves farms and homes around San Diego. His district has agreed to buy almost 15% of the Carlsbad plant's output. Poseidon says it has signed 30-year contracts with nine local water districts to sell all the water; about 40% would go to the city of Carlsbad.
The project has attracted big financial partners. In May, General Electric Co. said it had invested in it and would provide filtration technology. In September, Citigroup Inc.'s sustainable-development-investments unit became the lead investor in closely held Poseidon, formed in 1995 by former GE executives and private-equity firm Warburg Pincus. Andrew de Pass, the Citigroup unit's managing director, says the need for long-term water sources drove the investment. He declined to specify how much Citigroup invested.
Poseidon hopes to break ground this year and deliver water no later than 2011, providing it wins approval for its plans to mitigate the plant's impact on marine life and to offset its carbon-dioxide emissions.
The plant would initially take the saltwater discharged from an adjacent power plant that uses it for cooling, and later take water directly from the Pacific. Two sets of filters purify the water. The first set, thin tubes resembling rows of angel-hair pasta, blocks relatively large particles. The seawater is then pumped at very high pressure through dense membranes to remove salt, in a process called reverse osmosis.
This process uses a lot of electricity, contributing to its big price tag. Poseidon plans to sell the water for about $950 per acre-foot. That compares with an average $700 an acre-foot that local agencies now pay for water. (An acre-foot is 325,851 gallons, enough water for four people a year.) The Metropolitan Water District, a wholesale supplier to 18 million Southern Californians, will subsidize the difference as a way to add new water sources to the region. Poseidon President Walter Winrow says Poseidon will raise its price as local agencies pay more for water from other sources.
Peter Gleick, head of environmental think-tank Pacific Institute, says the costs of desalination projects tend to increase from those projected by sponsors, because of energy expenses and environmental requirements. "What people claim is always a little different," says Mr. Gleick.
There are other obstacles. California coastal regulators and some environmentalists say desalination uses too much energy and kills fish when the water is processed. Two environmental groups Monday filed suit to block the plant, on the grounds that it will harm marine life. Peter MacLaggan, who oversees the Carlsbad project for Poseidon, says the plant would kill about two pounds of fish a day, or "less than the daily consumption of one pelican."
Some opponents are wary of Poseidon because it was originally the co-developer of the troubled Tampa plant. Poseidon and the engineering firm it was working with estimated in 1999 that the plant would cost $110 million to build and produce water costing an average of $677 an acre-foot.
Then two engineering firms involved in the plant ran into financial difficulties, slowing work on the project.
In 2002, Tampa Bay Water, the government agency building the plant, bought out Poseidon and took on plant oversight. Tampa Bay Water ultimately brought in other companies, including units of Spain's Acciona S.A. and Germany's RWE AG, to finish and run the plant.
Last month, years behind schedule, the plant was declared fully operational, producing more than 25 million gallons of drinking water a day. Exceeding the initial estimate, construction came to $158 million, and the desalinated water costs $1,100 an acre-foot. Tom Pankratz, a Houston-based consultant to Tampa Bay Water's lawyers and a spokesman for the IDA, says there was "sloppy work" across the board. Poseidon's president, Mr. Winrow, says the company "would have managed the construction more appropriately" if it had been allowed to finish the project.
Ken Herd, Tampa Bay Water's operations director, says the plant is mostly running smoothly and the region may build more plants. Desalination is "not the cheapest source of supply, but it's drought-proof," he says.
Southern California officials toured the Tampa Bay plant before signing with Poseidon on the Carlsbad plant. Poseidon has brought in Acciona and RWE'S American Water to design and operate it.
Meanwhile, improved membranes and pumping systems have sharply reduced electricity costs. G.G. Pique, chief executive of Energy Recovery Inc., which makes desalination technology for the plant, estimates it will cost the Carlsbad plant $1.10 in electricity to produce 1,000 gallons of water. That is down from $2.10 per 1,000 gallons at the mothballed Santa Barbara plant, which he was also involved in.
The push on the Carlsbad plant comes as the National Academy of Sciences nears completion of a report on the potential role of desalination in meeting U.S. water needs.
Water experts are watching closely. California regulators are mulling as many as 20 proposed seawater projects that could produce 500 million gallons of water a day for the state. Poseidon is planning a second major plant in Huntington Beach, about 60 miles north of Carlsbad. "We're excited about the prospects," says Mike Chrisman, California's Secretary of Water Resources.
Doosan awards ERI the energy recovery contract for Kuwait’s first large-scale seawater reverse osmosis (SWRO) desalination plant
0 comments Posted by Energy Recovery Inc. at 6:01 PMTampa, FL, September 16, 2008 - The Ministry of Electricity and Water (MEW) of Kuwait awarded Doosan Heavy Industries & Construction the 136,000 m3/day (36 million US gallons per day (MGD)) Shuwaikh Seawater RO Desalination Plant with Recarbonation system. Doosan Heavy Industries & Construction is executing the project on an EPC basis while Doosan Hydro Technology, the wholly owned US based subsidiary, will partially provide basic process design engineering, as well as detail engineering review services. Energy Recovery, Inc. (“ERI”) (NASDAQ:ERII), a global leader of ultra-high-efficiency energy recovery products and technology for desalination was also contracted for its innovative PX Pressure Exchanger (PX) technology for the Shuwaikh SWRO project.
Water sustainability is a growing concern in the Middle East and the Kuwaiti Ministry of Electricity and Water has taken proper measures to sustain a potable water supply for its communities. The Plant is Kuwait’s first seawater desalination plant using RO technology. It will supply drinking water for 450,000 residents in Kuwait City. Under the contract, Doosan will design and build the plant, which is to be built near Shuwaikh port, as well as supply equipment and materials. The project is scheduled for completion in September 2010.
Doosan selected ERI’s largest commercially available 65-Series product, the PX-260 energy recovery device due to its high efficiency, flexibility and small footprint. The project will include 187 PX-260 PX Pressure Exchanger® energy recovery devices which will save an estimated 12.7 megawatts of power. ERI and Doosan also teamed up for the 150,000 m3/day (39.6 MGD) Al Shuaibah III Expansion SWRO Desalination Plant in September of 2007.
Dr. Richard Stover, ERI Chief Technology Officer stated, “We are excited about winning this project in Kuwait. Our ground-breaking work in the early 1990’s at the Kuwait Institute of Scientific Research (KISR) Laboratories laid the foundation for our innovative PX technology. It’s with great pleasure that we are able to give back to the region”, Dr. Stover continued. ERI has several desalination plants throughout the Middle East and North Africa engaging its PX technology. From large plants in Algeria and the UAE to smaller plants throughout Egypt and Saudi Arabia; ERI has focused its efforts on providing the region with advanced energy recovery solutions. The company has a regional sales office in Dubai.
About ERI(R)
Energy Recovery, Inc. (ERI) is a leading manufacturer of energy recovery devices, which by significantly reducing energy consumption is helping make desalination affordable. ERI's PX Pressure Exchanger(R) technology (PX(R)) is a rotary positive displacement pump that recovers energy from the high pressure waste stream of sea water reverse osmosis systems at up to 98% efficiency with no downtime or scheduled maintenance.
The company has research, development and manufacturing facilities in the San Francisco technology corridor as well as direct sales offices and technical support centers in key desalination hubs such as Madrid, UAE, Shanghai and Florida. ERI service representatives are based in Algeria, Australia, China, India, Korea, Mexico, Taiwan and the Caribbean.
As the demand for clean, potable water increases; ERI is poised to face the global challenges ahead. For more information on ERI and PX technology, please visit www.energyrecovery.com.
Former Bekaert/PROTEC and Codeline Executive, Doug Eisberg Joins ERI to Direct PX Technology Application Development
0 comments Posted by Energy Recovery Inc. at 6:13 PMSAN LEANDRO, Calif., Sep 09, 2008 (BUSINESS WIRE) -- Energy Recovery, Inc. ("ERI") (NASDAQ:ERII), a global leader of ultra-high-efficiency energy recovery products and technology for desalination, announced that the company recruited seasoned water treatment applications veteran and membrane housing expert Douglas Eisberg to be the company's Product Director.
As Product Director, Doug's responsibilities include identifying new applications for PX technology, promoting PX technology for brackish water desalination applications and assisting with the development of future PX device and pump designs. He will also help develop strategic collaborative relationships throughout the industry.
Prior to joining ERI, Doug worked for 17 years at Advanced Structures Inc., the makers of CodeLine (Pentair Water) pressure vessels, where he managed the development, engineering and sales departments. He was instrumental in the design of many composite membrane housing features now considered industry standards and holds several related international patents. In addition, Doug was the founder and President of PROTEC (Bekaert Progressive Composites) membrane pressure vessels.
Doug serves as the Chairman of the American Society of Mechanical Engineers (ASME), Boiler and Pressure Vessel Code Section X Subcommittee. He is also a Director in the American Membrane Technology Association (AMTA) and has served as the Chairman of the Nomination Committee. In addition, Doug is a board member of the International Desalination Association (IDA) as the Liaison for AMTA.
Dr. Richard Stover, ERI CTO said "As one of the most accomplished and best known figures in desalination, we are proud to have Doug join our team. His lifetime experience in the water industry coupled with his creative and analytical capabilities will be important contributions to ERI's strategic growth initiatives."
About ERI(R)
Energy Recovery, Inc. (ERI) is a leading manufacturer of energy recovery devices, which by significantly reducing energy consumption is helping make desalination affordable. ERI's PX Pressure Exchanger(R) technology (PX(R)) is a rotary positive displacement pump that recovers energy from the high pressure waste stream of sea water reverse osmosis systems at up to 98% efficiency with no downtime or scheduled maintenance.
The company has research, development and manufacturing facilities in the San Francisco technology corridor as well as direct sales offices and technical support centers in key desalination hubs such as Madrid, UAE, Shanghai and Florida. ERI service representatives are based in Algeria, Australia, China, India, Korea, Mexico, Taiwan and the Caribbean.
As the demand for clean, potable water increases; ERI is poised to face the global challenges ahead. For more information on ERI and PX technology, please visit www.energyrecovery.com.
Andalucia, Spain Seawater Desalination Plant Utilizes Award Winning PX(R) Technology
0 comments Posted by Energy Recovery Inc. at 12:32 AMSAN LEANDRO, Calif.--(BUSINESS WIRE)--Sept. 3, 2008--Energy Recovery, Inc. ("ERI") (NASDAQ:ERII), a global leader of ultra-high-efficiency energy recovery products and technology for desalination, announces that the Spanish joint venture of FCC / AQUALIA / BEFESA group of companies awarded the contract for energy recovery equipment for its Bajo Almanzora seawater desalination project to ERI. The plant will supply 60,000 m3/day (15.9 MGD) of fresh water to the region.
The design, build and operate seawater desalination project was awarded to the partnership of FCC/AQUALIA and BEFESA in August 2007 by Acuamed, the Spanish governmental water authority. Spanish companies have played a leadership role in designing and building desalination plants world-wide. The plant is located in the province of Almeria, Andalucia region, along the southeastern border of Spain. It is currently under construction and is scheduled to produce water in 2009. The Bajo Almanzora seawater desalination plant will supply water to one of the warmest provinces in the country where the level of rainfall is one of the lowest in Europe, with much of the area containing semi-arid and desert-like landscapes.
ERI PX(R) technology was specified for the project. ERI will supply 50 PX-220 energy recovery devices to operate in the first-stage of the reverse osmosis process. It is estimated that this technology will save the project over 5 mega-watts of high-pressure pump power. Last year, Befesa and ERI teamed to provide and energy recovery solution to India's largest desalination plant located in Chennai.
ERI's Vice President, of the Mega Projects Division stated, "As with all our projects, we feel very satisfied when our customers build desalination plants that consider energy recovery as a key component of the overall solution."
About ERI(R)
Energy Recovery, Inc. (ERI) is a leading manufacturer of energy recovery devices, which by significantly reducing energy consumption is helping make desalination affordable. ERI's PX Pressure Exchanger(R) technology (PX(R)) is a rotary positive displacement pump that recovers energy from the high pressure waste stream of sea water reverse osmosis systems at up to 98% efficiency with no downtime or scheduled maintenance.
The company has research, development and manufacturing facilities in the San Francisco technology corridor as well as direct sales offices and technical support centers in key desalination hubs such as Madrid, UAE, Shanghai and Florida. ERI service representatives are based in Algeria, Australia, China, India, Korea, Mexico, Taiwan and the Caribbean.
As the demand for clean, potable water increases; ERI is poised to face the global challenges ahead. For more information on ERI and PX technology, please visit www.energyrecovery.com.
United Arab Emirates Desalination Energy Recovery Contract Awarded to ERI
0 comments Posted by Energy Recovery Inc. at 12:26 AM91,000 m3/day (24 million gallons per day) Hamriyah Seawater
Desalination Plant in Sharjah Selects PX Technology
SAN LEANDRO, Calif.--(BUSINESS WIRE)--Aug. 5, 2008--Energy Recovery, Inc. ("ERI") (NASDAQ:ERII), a global leader of ultra-high-efficiency energy recovery products and technology for desalination, announced that it has been awarded a contract to provide the energy recovery technology for the Hamriyah (Phase 1) Power Station Seawater Reverse Osmosis (SWRO) Desalination Plant. Aqua Engineering GmbH and ERI have signed a supply agreement for PX(R) energy recovery devices for the 91,000 cubic meters per day (m3/day) (24 million gallons per day (MGD)) plant to be located in Sharjah, United Arab Emirates.
The plant was awarded to Austrian company Aqua Engineering GmbH, a subsidiary of Christ Water Technology AG, by the Sharjah Electricity and Water Authority (SEWA). The overall capacity of the Hamriyah facility will be 455,000 m3/day (120 MGD) of fresh water by reverse osmosis technology and 181,000 m3/day (48 MGD) by a thermal desalination process called multiple effect distillation (MED). This phase of the project will include 104 PX-260 PX Pressure Exchanger(R) energy recovery devices which will save an estimated 13 megawatts of power. Designed with a total of eight (8) SWRO trains operating in parallel, the devices will provide fail-safe redundancy and reliability with little or no down-time. Currently, the plant is under construction and scheduled for start-up in 2009. Initial work on the site included a 600 MW power plant. The SEWA project will eventually supply 2000 MW of power and 637,000 m3/day (168 MGD) of desalinated water.
In late 2007, ERI announced the release of its PX-260 device, the latest addition to its PX technology line of products. The PX-260 is part of the 65-Series product line and is the Company's largest commercially available energy recovery device, handling brine flow rates of up to 260 gallons per minute (59 cubic meters per hour) - nearly 20% greater capacity than ERI's former largest device. It operates at the highest efficiency, providing the best overall energy savings and lowest cost of ownership of any commercially available energy recovery solution.
The Middle East has been a mainstay for ERI with many small to large plant installations across the region, ranging from small hotels in Egypt and UAE to larger projects in Saudi Arabia, among others. The company has a regional sales office in Dubai.
"This is the fourth plant within a few years for which we have chosen PX technology. Having installed them in various plant sizes in Oman and UAE, we found these devices working very reliably and most efficiently," stated Guido Codemo, Process Engineer for Aqua Engineering.
About ERI(R)
Energy Recovery, Inc. (ERI) is a leading manufacturer of energy recovery devices, which by significantly reducing energy consumption is helping make desalination affordable. ERI's PX Pressure Exchanger(R) technology (PX(R)) is a rotary positive displacement pump that recovers energy from the high pressure waste stream of sea water reverse osmosis systems at up to 98% efficiency with no downtime or scheduled maintenance.
The company has research, development and manufacturing facilities in the San Francisco technology corridor as well as direct sales offices and technical support centers in key desalination hubs such as Madrid, UAE, Shanghai and Florida. ERI service representatives are based in Algeria, Australia, China, India, Korea, Mexico, Taiwan and the Caribbean.
As the demand for clean, potable water increases; ERI is poised to face the global challenges ahead. For more information on ERI and PX technology, please visit www.energyrecovery.com.
The new pressure exchanger (PX) device transfers the energy from the concentrate stream directly to the feed stream. This direct, positive displacement approach results in a net transfer efficiency of over 95%. Although application of the PX technology is simple in both theory and practice, in order to get the most benefit from this technology it is important to reconsider the SWRO design and operation approach. Pertinent design considerations include pre-filtration, conversion rate optimization; pump selection, and operating pressures. Some important operating procedures and characteristics are start up, high pressure regulation, conversion rate optimization, flow balancing, and shutdown. Furthermore, it will be shown that these considerations affect the design and operation of SWRO systems counter-intuitively and may possibly reverse given standards that have been developed over the past 20 years of SWRO design.
There has been a recent proliferation of commercially available energy recovery devices based on the positive displacement direct pressure exchange approach. This increased interest is driven by the fact that the technology can reduce the energy consumption of an SWRO system by as much as 60%. Since energy costs are rising and can consume as much as 75% of the total operating costs of an SWRO plant, it is important that the technology be encouraged and disseminated throughout the industry. Although the authors of this paper are directly associated with Energy Recovery, Inc., a leading company in pressure exchanger technology, the principles and theories presented in this paper will be applicable to all devices based on the positive displacement, direct pressure exchange approach.
4.0 START AND STOP PROCEDURES
Starting and stopping an SWRO system designed around the PX pressure exchanger device is actually simpler than with systems designed around other technologies such as regulating valves, turbos and Pelton wheels. This is because of the self-balancing nature of SWRO systems designed around pressure exchanger technologies.
4.2 System start up sequence
Start up of an SWRO plant designed around the PX device is very simple. The first step is to start the raw water supply pump. At this point the system will begin to fill with water and the PX may or may not start to spin. Next, start the high-pressure boost pump. The associated pressure drops through the RO membranes and PX combine with the high-pressure boost pump curve to dictate the reject flow rate into and seawater flow rate out of the PX unit. This means that once the high-pressure boost pump is running and has stabilized the reject flow is now running at or very near the normal flow rate for the plant. Now it is time to start the main high-pressure pump, which will pressurize the RO system. The system will reach the exact pressure required to produce the amount of product water being injected to the RO system by the main high-pressure pump. The membranes create the back-pressure in the system and now act like the pressure-regulating valve. It will take 5-10 seconds for a typical system to pressurize once the main high-pressure pump is started. It may be advisable to install a high-pressure bypass valve at the outlet of the RO membranes that can be closed slowly at start up. This will allow the operator to control of the rate at which the RO system reaches full operating pressure.
4.3 SYSTEM SHUT DOWN SEQUENCE
First stop the main high-pressure pump. After approximately 30 seconds the pressure in the RO system will drop to around 27 bar. At this point it is proper to stop the high-pressure booster pump and raw water supply pump. It should be noted that because the high-pressure side of the PX is sealed from the low pressure side of the PX the high pressure RO portion of the plant can maintain significant pressure for an extended period of time.
4.4 Fresh water flush
If the SWRO system is going to be shut down for an extended period of time it is required to fresh water flush the RO membranes and pressure exchanger in order to inhibit biological growth and fouling. Start by supply the RO system with un-chlorinated fresh water at the normal system feed pressure. Next run the high-pressure booster pump until all of the seawater has been purged from the RO membranes. It may also be desirable to also run the high-pressure pump for a few seconds during this process to ensure that it gets a complete flush as well.
5.0 FLOW CONTROL AND BALANCING THE SYSTEM
Flow rates and pressures in a SWRO plant will vary slightly over the life of a plant. Variations may be due to temperature, membrane fouling, seasonal feed salinity variations, etc. The following designs and procedures should be used to control these variables.
5.1 High Pressure Reject and Seawater Feed Flow Control
In order to control the high-pressure reject and feed flow rates, adjustment of the pressure and flow supplied by the high-pressure booster pump is typically required. Recommended practice is to use a high pressure booster pump with some additional capacity, and control its flow and pressure with a variable frequency drive or control valve. A high-pressure flow meter can be used to determine the amount of reject and feed water flowing through the high-pressure side of the pressure exchanger device. Remember that the high-pressure reject water and feed water are hydraulically connected and are separated only by a water barrier/piston. It is also possible to infer the high-pressure flow rates from the pressure drops across the pressure exchanger and/or high-pressure boost pump. Increasing and decreasing these flow rates is how we decrease and increase respectively the conversion rate of the RO system independently of the product water being produced.
5.2 Low Pressure Reject and Seawater Feed Flow Control
In order to control the flow rates of the low-pressure feed and reject water, adjustments to the low pressure seawater inlet pressure to the PX should be made. Recommended practice is to install a valve at the low-pressure seawater inlet of the PX unit(s). Remember that the low-pressure seawater and reject water are hydraulically connected and are separated only by a water barrier/piston. The low pressure seawater and reject flow rates can be determined by installing a flow meter at the low-pressure seawater inlet of the PX.
5.3 Balancing the pressure exchanger using flow meters
All flows in and out of the Pressure Exchanger must be approximately balanced. The following equation applies to this process:
High pressure seawater outlet flow = Low pressure seawater inlet flow
Determine the desired amount of high-pressure seawater outlet flow, which is approximately equal to the reject flow for your system. Adjust the variable frequency drive or control valve on the high pressure booster pump until that flow rate is achieved as seen at the high-pressure flow meter. In the absence of a high-pressure flow meter it is also possible to infer the flow rates from the pressure drops across the boost pump and/or pressure exchanger(s).
Adjust the low-pressure seawater inlet valve until the low-pressure seawater inlet flow equals the high pressure seawater outlet flow.
If the low pressure seawater inlet flow is less than the high pressure seawater outlet flow excessive intermixing of reject with the feed will occur which will result in lower quality permeate, increased feed pressure and higher energy consumption. If the low-pressure seawater inlet flow is greater than the high-pressure seawater outlet flow, treated feed water is being wasted and dumped to the low-pressure reject drain.
6.0 CONCLUSION
The PX is a new pressure exchanger device that promises to revolutionize SWRO design. The device affects the design and operation of SWRO systems in several counter-intuitive ways. As we have discussed, lower conversions rates in the order of 30-40% actually yield lower energy profiles than higher conversion rates. Furthermore, these systems operate at lower pressures and produce better water quality.
The fact that the main high pressure pump flow equals the permeate flow means that we can now achieve SWRO systems with nearly 100% conversion rates when considering the pumping power that is being applied. This fact also means that for any given high pressure pump, systems that are 2-3 times larger can be achieved with that same pump.
The PX device now makes it possible to adjust the conversion rate of an SWRO plant independently of product water production. This means that the conversion rate can now be simply and directly used to optimize the efficiency of the RO membranes rather than having to balance it against energy consumption, product quality, membrane pressure limits, and so on.
It is clear that this device is an extremely efficient approach to energy recovery, and that the SWRO systems of today and the future will consume far less energy than those of yesterday. However, the impact that this device will have on design concerns such as the conversion rate, water quality, and operating pressures will surely surprise us all.
The new pressure exchanger (PX) device transfers the energy from the concentrate stream directly to the feed stream. This direct, positive displacement approach results in a net transfer efficiency of over 95%. Although application of the PX technology is simple in both theory and practice, in order to get the most benefit from this technology it is important to reconsider the SWRO design and operation approach. Pertinent design considerations include pre-filtration, conversion rate optimization; pump selection, and operating pressures. Some important operating procedures and characteristics are start up, high pressure regulation, conversion rate optimization, flow balancing, and shutdown. Furthermore, it will be shown that these considerations affect the design and operation of SWRO systems counter-intuitively and may possibly reverse given standards that have been developed over the past 20 years of SWRO design.
There has been a recent proliferation of commercially available energy recovery devices based on the positive displacement direct pressure exchange approach. This increased interest is driven by the fact that the technology can reduce the energy consumption of an SWRO system by as much as 60%. Since energy costs are rising and can consume as much as 75% of the total operating costs of an SWRO plant, it is important that the technology be encouraged and disseminated throughout the industry. Although the authors of this paper are directly associated with Energy Recovery, Inc., a leading company in pressure exchanger technology, the principles and theories presented in this paper will be applicable to all devices based on the positive displacement, direct pressure exchange approach.
1.0 INTRODUCTION
The PX is a new pressure exchanger device that transfers the energy from the concentrate/reject stream directly to the feed stream in a cylindrical rotor with longitudinal ducts. The rotor spins inside a sleeve between two end covers that divide the rotor into high and low pressure halves. When designing a seawater RO system using the new pressure exchanger device it is only necessary to reconsider the high pressure portion of the system. This is because this is the only portion that differs from earlier RO designs. Pertinent design considerations include conversion rate optimization, pump selection, and operating pressures. Some important operating procedures and characteristics are start up, high pressure regulation, conversion rate optimization, flow balancing, and shutdown. Although application of the pressure exchanger is simple in both theory and practice it is vastly different from typical SWRO design and operation. These differences affect the design and operation of SWRO systems in surprising ways that can be used to improve other aspects of system performance beyond the scope of energy consumption alone.
2.0 PRINCIPLE OF OPERATION
The PX unit utilizes the principle of positive displacement to transfer the energy in the reject stream directly to the feed stream. It is interesting to note that the reject stream is continuously and directly connected to the feed stream. This direct connection allows a real net transfer efficiency of energy from the reject stream to the feed stream of over 95%. The PX device uses a cylindrical rotor with longitudinal ducts parallel to its rotational axis to transfer the pressure energy from the concentrate/reject stream to the feed stream.
The rotor spins inside a sleeve between two end covers with port openings for low and high pressure. The low-pressure side of the rotor fills with seawater while the high-pressure side discharges seawater. The rotation simply facilitates the valving mechanism, which is to transport the ducts from one side to the other.
By rotation the ducts are exposed to the low pressure feed water, which fills the duct and displaces the reject water. The rotor continues to rotate and is exposed to the high-pressure concentrate, which fills the duct from the opposite direction, and displaces the feed water at high pressure. This rotational action is similar to a Gatling machine gun firing high-pressure bullets and being refilled with new seawater cartridges from the muzzle. A liquid piston moves back and forth inside each duct creating a barrier that inhibits mixing between the concentrated reject and new seawater streams. At 1500 rpm one revolution is completed every 1/25 second. Due to this short cycle time, membrane feed water concentrations typically increase only 1%-2%. See Figure 4-1 below.
Applying PX pressure exchanger technology to SWRO is different from conventional energy recovery device system design, but in practice is quite simple. The reject brine from the SWRO membranes is passed into the PX unit, where its pressure energy is transferred directly to a portion of the incoming raw seawater at up to 97% efficiency. This seawater stream, nearly equal in volume and pressure to the reject stream, then passes through a high-pressure booster pump, not the main high-pressure pump. This booster pump is making up the pressure losses across the RO membrane (approx. 2 bar), PX unit(s) (approx. 1 bar) and piping losses (approx. 0.5 bar). The total head provided by the boost pump is typically around 3.5 bar. See figure 4-2 and table 4-1 below.
It is important to notice that the PX and associated boost pump are handling nearly 100% of the reject flow. The size of the main high-pressure pump has been reduced to a make up pump for the permeate flow that is exiting the RO system. Product water flow and reject flow are being provided by two independent pumping systems and therefore are independent of one another.
Since the PX unit is providing nearly 100% of the reject flow at over 95% efficiency there is very little energy penalty associated with increasing this flow and thereby lower the conversion rate of the RO system. At lower conversion rate the pressure required to produce the same amount of product water is lower. Since the main high-pressure pump flow equals the product water flow an energy savings is actually achieved at lower conversion rates.
3.0 CONVERSION OPTIMIZATION
There are many factors that effect RO conversion optimization but none has been more influential than energy consumption. This is because energy costs can be as much as 75% of the entire operating cost of an SWRO plant. In the past the sewater to fresh water conversion rate has had a major and direct impact on the energy consumption of an RO plant. This is because of the inherent shortcomings of the energy recovery and pumping devices that have been used such as the Pelton wheels, turbines, and pumps. These technologies have real/overall net transfer efficiencies of 40-70 percent and are designed to pump the entire feed flow of an RO plant. Therefore at lower conversion rates these inefficient devices are pumping more water. The only way to make these devices pump less water and thereby consume less energy is to increase the conversion rate of the RO system. This is all very logical, and with rising energy costs it is natural that SWRO systems are now being designed at the membrane challenging conversion rates of 50-60%.
System designs with the PX device are different. This is because the PX, a 95% efficient device, is pumping the reject water independently of the product water being produced. The overall energy consumption of an SWRO plant using the PX device has a low point at conversion rates typically between 30-40%. Outside these conversion points the plant will start to consume slightly higher amounts of power. See figure 3 below.
It is important to remember that with the PX device the main high pressure pump flow approximately equals the product water flow. At lower conversion rates it requires lower pressure to produce the same amount of product water. Therefore, the main high-pressure pump will consume less power pumping against less pressure at the lower conversion rates. This phenomenon yields the net energy decrease shown in Figure 3.
Another important point to consider is water quality. In the past, system design had to balance high conversion rate with good water quality. In high salinity applications this has been a difficult challenge. Figure 4 below shows how a lower conversion rate yields better water quality.
Logically combining the kWh/m3 vs Conversion Rate curve of Figure 3 with the diminishing water quality curve as the conversion rate increases in figure 4 shows us that there are good reasons now to consider SWRO designs with lower conversion rates. There are also additional benefits associated with lower conversion rate designs such as ease of operation, fewer cleaning cycles, longer membrane life and a better balance of flux (GFD) from the lead element to the end element in an RO pressure vessel. Figure 5 below shows how GFD is balanced as the system conversion rate lowers(5).
Of course decreasing the system conversion rate does have its disadvantages mainly in increasing the size of the pretreatment system. This effect is less significant in smaller systems under 1000 m3/day because of the less expensive piping materials, pressure media filtration systems and other components typically employed in these systems. However on larger plants using open seawater intakes with large-scale gravity feed media filtration systems, and when the chemical additions associated with coagulation are significant operating costs, conversion rates between 45-50% may be more practical.